A representative organization leading the businesses of air cleaning
and environmental control industry
HH mark is granted to the products which pass strict tests by certified test agencies in accordance with collective standards for humidifier including Humidification capablity, Power Consumption, Microbe contamination, Noise to provide reliable humidifier by the Korea Air Cleaning Association.
It aims at performing autonomous quality management for humidifiers to protect customers and contribute to quality upgrade.
It shall be applied to the safety and performance of indoor humidifier that is installed in a general house and office room to raise indoor relative humidity and that uses single-phase alternating current and whose rated humidifying capacity is less than 10L/h.
1) General performance
Item | Certification criteria | |
---|---|---|
Unit | Criteria | |
Humidification capacity | mL/h | Rated humidifying capacity 100% or more |
Electric power consumption | W | Rated electric power consumption 100% or less |
Microbial contamination | CFU/㎥ | less than 30 |
Noise level | 2) Noise level performance criteria | |
2) Noise level performance criteria
Range | Criteria | Note | |
---|---|---|---|
Humidifying capacity (mL/h) |
500 or more | less than 55 dB(A) | ※ When the humidifying function is an additional function, the noise lever criteria follow the group standard certification criteria for the main function product.
But, It is applied only when the group standard certification of the main function product is obtained. |
300 or more and less than 500 | less than 50 dB(A) | ||
300 or less | less than 45 dB(A) | ||